AboutBlogContact

Hardware Installation

Detailed instructions and wiring diagrams for the boneIO controller, including power, inputs, outputs, and communication buses.

Connecting Digital Inputs

Digital inputs are used for connecting switches and sensors. By default, they are ground-controlled.

  1. Connect one of the wires from a momentary switch to the common GND (ground) terminal.
  2. Connect the other wire to the desired input terminal (e.g., IN01).
  3. Pressing the switch will short the input to ground, which will be interpreted as an "on" signal.

Logical diagram of connecting digital input

GND or +

The default input behavior (ground-controlled) can be changed via the internal switch. Please see the switch location below.

  • Down (Default): GND control.
  • Up: High-potential control.